The HYDROCAL 1001+ is a permanently-installed composite gas-in-oil sensor for the analysis of six dissolved key fault gases such as Hydrogen (H2), Carbon Monoxide (CO), Methane (CH4), Acethylene (C2H2), Ethylene (C2H4), and Ethane (C2H6). To detect an even wider range of potential transformer faults, the HYDROCAL 1001+ analyses additionally the content of Moisture (H2O) in the transformer oil.

The HYDROCAL 1003 is an online monitoring system permanently mounted on the transformer. It measures continuously Moisture in Oil (H2O) and the most important faults gases Hydrogen (H2) and Carbon Monoxide (CO).

The new HYDROCAL 1004 genX is the first truly maintenance-free multi-gas online DGA solution combining proven near infrared (NIR) measuring technology with vacuum protected membrane extraction.
As Hydrogen (H2) is involved in nearly every fault of the insulation system of power transformers and Carbon Monoxide (CO) is a sign of an involvement of the cellulosic / paper isolation the presence and increase of Acetylene (C2H2) further classifies the nature of a fault as overheating, partial discharge or high energy arcing.

The HYDROCAL 1005 is a permanently-installed multi-gas-in-oil analysis system with transformer monitoring functions. It allows for the individual measurement of Moisture in Oil (H2O) and the key gases Hydrogen (H2), Carbon Monoxide (CO), Acetylene (C2H2) and Ethylene (C2H4) dissolved in transformer oil.

The new HYDROCAL 1006 genX is the first truly maintenance-free multi-gas online DGA solution combining proven near infrared (NIR) measuring technology with vacuum protected membrane extraction.
As Hydrogen (H2) is involved in nearly every fault of the insulation system of power transformers and Carbon Monoxide (CO) is a sign of an involvement of the cellulosic / paper isolation the presence and increase of Acetylene (C2H2) further classifies the nature of a fault as overheating, partial discharge or high energy arcing.
The additional measurement of Ethylene (C2H4) and Methane (CH4) serves for further analysis, e.g. Duval triangle according IEC 60599.

The HYDROCAL 1008 is a permanently-installed multi-gas-in-oil analysis system with transformer monitoring functions. It allows for the individual measurement of Moisture in Oil (H2O) and the key gases Hydrogen (H2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Methane (CH4), Acetylene (C2H2), Ethylene (C2H4) and Ethane (C2H6) dissolved in transformer oil.

The HYDROCAL 1009 is a permanently installed multi-gas-in-oil analysis system with transformer monitoring functions. It individually measures, Moisture in Oil (H2O) and the key gases Hydrogen (H2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Methane (CH4), Acetylene (C2H2), Ethylene (C2H4), Ethane (C2H6) and Oxygen (O2) dissolved in transformer oil.

The HYDROCAL 1011 genX P is a portable device for the analysis of dissolved and free gases from the isolation fluid of oil-filled power transformers and other electrical equipment. It individually measures moisture in oil (H2O) and the key gases hydrogen (H2), carbon monoxide (CO), carbon dioxide (CO2), methane (CH4), acetylene (C2H2), ethylene (C2H4), ethane (C2H6), oxygen (O2), nitrogen (N2) and propane (C3H8) dissolved in transformer oil.