This website uses session cookies to provide the best possible functionality. Session cookies ensure that you are recognized when you move from page to page within our site and that any information you have entered is remembered. You can choose to accept cookies by changing the settings in your browser. For more information please refer to our Privacy Policy.

» PRIVACY POLICY
» CLOSE THIS BOX
Logo MTE Meter Test Equipment AG
MTE Meter Test Equipment AG
Logo MTE Meter Test Equipment AG
Logo MTE Meter Test Equipment AG

COMPARISONS HYDROCAL

HYDROCAL 1001+

The HYDROCAL 1001+ is a permanently-installed composite gas-in-oil sensor for the analysis of six dissolved key fault gases such as Hydrogen (H2), Carbon Monoxide (CO), Methane (CH4), Acethylene (C2H2), Ethylene (C2H4), and Ethane (C2H6). To detect an even wider range of potential transformer faults, the HYDROCAL 1001+ analyses additionally the content of Moisture (H2O) in the transformer oil.

HYDROCAL 1003

The HYDROCAL 1003 is an online monitoring system permanently mounted on the transformer. It measures continuously Moisture in Oil (H2O) and the most important faults gases Hydrogen (H2) and Carbon Monoxide (CO).

HYDROCAL 1004 genX

The new HYDROCAL 1004 genX is the first truly maintenance-free multi-gas online DGA solution combining proven near infrared (NIR) measuring technology with vacuum protected membrane extraction.
As Hydrogen (H2) is involved in nearly every fault of the insulation system of power transformers and Carbon Monoxide (CO) is a sign of an involvement of the cellulosic / paper isolation the presence and increase of Acetylene (C2H2) further classifies the nature of a fault as overheating, partial discharge or high energy arcing.

HYDROCAL 1005

The HYDROCAL 1005 is a permanently-installed multi-gas-in-oil analysis system with transformer monitoring functions. It allows for the individual measurement of Moisture in Oil (H2O) and the key gases Hydrogen (H2), Carbon Monoxide (CO), Acetylene (C2H2) and  Ethylene (C2H4) dissolved in transformer oil.

HYDROCAL 1006 genX

The new HYDROCAL 1006 genX is the first truly maintenance-free multi-gas online DGA solution combining proven near infrared (NIR) measuring technology with vacuum protected membrane extraction.
As Hydrogen (H2) is involved in nearly every fault of the insulation system of power transformers and Carbon Monoxide (CO) is a sign of an involvement of the cellulosic / paper isolation the presence and increase of Acetylene (C2H2) further classifies the nature of a fault as overheating, partial discharge or high energy arcing.
The additional measurement of Ethylene (C2H4) and Methane (CH4) serves for further analysis, e.g. Duval triangle according IEC 60599.

HYDROCAL 1008

The HYDROCAL 1008 is a permanently-installed multi-gas-in-oil analysis system with transformer monitoring functions. It allows for the individual measurement of Moisture in Oil (H2O) and the key gases Hydrogen (H2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Methane (CH4), Acetylene (C2H2), Ethylene (C2H4) and  Ethane (C2H6) dissolved in transformer oil.

HYDROCAL 1009

The HYDROCAL 1009 is a permanently installed multi-gas-in-oil analysis system with transformer monitoring functions. It individually measures, Moisture in Oil (H2O) and the key gases Hydrogen (H2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Methane (CH4), Acetylene (C2H2), Ethylene (C2H4), Ethane (C2H6) and Oxygen (O2) dissolved in transformer oil.

HYDROCAL 1011 genX P

The HYDROCAL 1011 genX P is a portable device for the analysis of dissolved and free gases from the isolation fluid of oil-filled power transformers and other electrical equipment. It individually measures moisture in oil (H2O) and the key gases hydrogen (H2), carbon monoxide (CO), carbon dioxide (CO2), methane (CH4), acetylene (C2H2), ethylene (C2H4), ethane (C2H6), oxygen (O2), nitrogen (N2) and propane (C3H8) dissolved in transformer oil.