This website uses session cookies to provide the best possible functionality. Session cookies ensure that you are recognized when you move from page to page within our site and that any information you have entered is remembered. You can choose to accept cookies by changing the settings in your browser. For more information please refer to our Privacy Policy.

» PRIVACY POLICY
» CLOSE THIS BOX
Logo MTE Meter Test Equipment AG
MTE Meter Test Equipment AG
Logo MTE Meter Test Equipment AG
Logo MTE Meter Test Equipment AG

MARKETING TOOLS

HYDROCAL 1004 genX

The new HYDROCAL 1004 genX is the first truly maintenance-free multi-gas online DGA solution combining proven near infrared (NIR) measuring technology with vacuum protected membrane extraction.
As Hydrogen (H2) is involved in nearly every fault of the insulation system of power transformers and Carbon Monoxide (CO) is a sign of an involvement of the cellulosic / paper isolation the presence and increase of Acetylene (C2H2) further classifies the nature of a fault as overheating, partial discharge or high energy arcing.

Enlit Asia '21

Article from Melissa Fitzgerald -

Smart Meter Testing Made Easy with New Portable Devices

PTS 3.3 genX

The PTS 3.3 genX portable test system consists of an integrated three-phase current and voltage source unit and a three-phase electronic reference standard of accuracy class 0.05. Characteristic features of the PTS 3.3 genX are its wide measuring range, high accuracy and high tolerance to unwanted external influences.

CheckSystem 2.1

The CheckSystem 2.1 portable test system consists of an integrated single-phase current source and a single-phase electronic reference standard of accuracy class 0.2. Characteristic features of the CheckSystem 2.1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences.

CheckMeter 2.1

CheckMeter 2.1

The CheckMeter 2.1 Portable Working Standard is a single-phase portable electronic meter test unit in accuracy class 0.2%, used for testing single phase electricity meters on site.

CheckSource 2.3

CheckSource 2.3 is a three-phase current source for currents up to
6 A.

PTS 400.3 PLUS

The PTS 400.3 PLUS system consists of a reference standard PRS 600.3 of class 0.02% and a programmable power source PPS 400.3, which is available in two versions of up to 12 A or 120 A.

PRS 600.3

The PRS 600.3 is a combination of a three-phase Portable Reference Standard of class 0.02% and an IEC 61000-4-30 Class A compatible Power Quality Analyzer with 3 voltage and 3 current channels.

CheckSystem 2.3

The CheckSystem 2.3 portable test system consists of an integrated three-phase 16 A current source unit and a three-phase electronic reference standard available in class 0.2.

CheckSystem 2.1

The CheckSystem 2.1 portable test system consists of an integrated single-phase 120 A current source unit and a single-phase electronic reference standard available in class 0.2.

Portable Test Equipment

Single and three phase portable test units available over a wide range of accuracy classes for on-site testing or laboratory use.

Stationary Test Equipment

Stationary Test Equipment

Single and three phase test systems are available with fixed meter test racks or with movable trolleys and gantries.

K2006

K2006

The K2006 is a class 0.01 three phase comparator which has been especially developed for use in universal laboratory and test areas.

CALPORT 300

CALPORT 300

The CALPORT 300 is a class 0.05 Reference Standard and an universal test system for the comprehensive investigation and commissioning of all components of a modern metering installation.

PWS 3.3

PWS 3.3

The PWS 3.3 is a combination of a three-phase Portable Working Standard of class 0.05% or 0.1% and an IEC 61000-4-30 Class A compatible Power Quality Analyzer with 3 voltage and 4 current channels.

CheckSource 2.3

The CheckSource 2.3 is a three-phase current source for currents up to 6 A. The test currents are generated with the same frequency and a user-defined phase shift to the voltages applied to the voltage inputs (phantom load). Alternatively the test currents can also be generated with a user defined frequency.

PPS 400.3

The PPS 400.3 is a powerful, portable three-phase current and voltage source. The source is available in 12 A or 120 A version.

CALPORT 300

The CALPORT 300 is an universal test system for the comprehensive investigation of all components of a modern metering installation. Characteristic features are its wide measuring range, the high accuracy and the small dependence of disturbing

CheckSource 2.3

CheckSource 2.3 is a three-phase current source for currents up to
6 A.

CheckMeter 2.3 genX

The CheckMeter 2.3 genX Portable Standard Meter is a three-phase portable electronic meter test unit of accuracy class 0.2, used for testing single and three-phase electricity meters on-site.

CheckSystem 2.3

CheckSystem 2.3

The CheckSystem 2.3 portable test system consists of an integrated three-phase 16 A current source unit and a three-phase electronic reference standard available in class 0.2.

CheckSystem 2.1

The CheckSystem 2.1 portable test system consists of an integrated single-phase 120 A current source unit and a single-phase electronic reference standard available in class 0.2.

MTE-F3-10.10

MTE-F3-10.10

Meter Test Station for 10 measurement positions, reference standard 0.05 %, electronic power source with 300 VA, IEC 1107 communication capability.

MTE-F3-20.20

MTE-F3-20.20

Meter Test Station for 20 measurement positions, reference standard 0.05 %, electronic power source with 300 VA, IEC 1107 communication capability.

PWS 2.3 genX

PWS 2.3 genX

The PWS 2.3 genX Portable Working Standard is a three-phase portable electronic meter test unit of accuracy class 0.1 %, used for testing single and three-phase electricity meters on site. The PWS 2.3 genX allows checking of all meter installation parameters and associated circuits.

HYDROCAL 1003

HYDROCAL 1003

The HYDROCAL 1003 is an online monitoring system permanently mounted on the transformer. It measures continuously the most important faults gases hydrogen (H2) and carbon monoxide (CO).

HYDROCAL 1005

HYDROCAL 1005

The HYDROCAL 1005 is a permanently-installed multi-gas-in-oil analysis system with transformer monitoring functions. It allows for the individual measurement of moisture and the key gases hydrogen (H2), carbon monoxide (CO), acetylene (C2H2) and ethylene (C2H4) dissolved in transformer oil.

HYDROCAL 1008

HYDROCAL 1008

The HYDROCAL 1008 is a permanently-installed multi-gas-in-oil analysis system with transformer monitoring functions. It allows for the individual measurement of moisture and the key gases hydrogen (H2), carbon monoxide (CO), carbon dioxide (CO2), methane (CH4), acetylene (C2H2), ethylene (C2H4) and ethane (C2H6) dissolved in transformer oil.

Metering International

Edition December 2004
"New Meter Test Equipment and Current Transformer Test System for Mongolia Electricity Company"

Metering International

Edition September 2005
"Instrument Transformer - The forgotten Link in the Accuracy Chain"

Metering International

Edition June 2006
"The Evolution of Meter Test Technology"

Metering International

Edition September 2006
"Instrument Transformer - A Racecar with the wrong Settings"

HYDROCAL 1006 genX

The new HYDROCAL 1006 genX is the first truly maintenance-free multi-gas online DGA solution combining proven near infrared (NIR) measuring technology with vacuum protected membrane extraction.
As Hydrogen (H2) is involved in nearly every fault of the insulation system of power transformers and Carbon Monoxide (CO) is a sign of an involvement of the cellulosic / paper isolation the presence and increase of Acetylene (C2H2) further classifies the nature of a fault as overheating, partial discharge or high energy arcing.
The additional measurement of Ethylene (C2H4) and Methane (CH4) serves for further analysis, e.g. Duval triangle according IEC 60599.

PWS 2.3 genX

The PWS 2.3 genX Portable Working Standard is a three-phase portable electronic meter test unit of accuracy class 0.1%, used for testing single and three-phase electricity meters on site. The unit can be used either with a direct connection in the range of 1 mA ... 12 A, or by using a set of 3 active 120 A error compensated UCT clamp-on CT’s.

CheckMeter 2.3 genX

The CheckMeter 2.3 genX Portable Standard Meter is a three-phase portable electronic meter test unit of accuracy class 0.2, used for testing single and three-phase electricity meters on-site.
The unit has direct voltage inputs and one UCT Universal Current Transducer input, which can be used with different independent transducers to measure the current with clamp-on CT’s or direct or with high voltage current sensors.

K 2006

The K2006 is a high accuracy comparator of accuracy class 0.01, especially suitable for use in metrological institutes and high precision measuring laboratories.

PRS 600.3

The PRS 600.3 is a combination of a three-phase Portable Reference Standard of accuracy class 0.02 and an IEC 61000-4-30 Class A compatible Power Quality Analyzer with 3 voltage and 3 current channels. The device is equipped with two 8.4” colours TFT VGA displays based on touch screen operation.

PTS 2.3 genX

The PTS 2.3 genX portable test system consists of an integrated three-phase current source unit and a three-phase electronic reference standard of accuracy class 0.1. Characteristic features of the PTS 2.3 genX are its wide measuring range, high accuracy and high tolerance to unwanted external influences.

PWS 3.3

The PWS 3.3 is a combination of a three-phase Portable Working Standard of accuracy class 0.05 or 0.1 and an IEC 61000-4-30 Class A compatible Power Quality Analyzer with 3 voltage and 4 current channels.

PPS 400.3

The PPS 400.3 is a powerful and portable three-phase current and voltage source. All test values are generated absolutely synthetically with a high degree of accuracy and stability.

PWS 2.3 genX / CheckMeter 2.3 genX

The PWS 2.3 genX Portable Working Standard is a three-phase portable electronic meter test unit of accuracy class 0.1%, used for testing single and three-phase electricity meters on site.

The CheckMeter 2.3 genX Portable Standard Meter is a three-phase portable electronic meter test unit of accuracy class 0.2, used for testing single and three-phase electricity meters on site.

MTE-F

Single- and three-phase, standardized and individual test systems are covering all legal metrological test requirements for simple meters, high precision multifunction meters, smart meters and reference standards.

HYDROCAL 1005

The HYDROCAL 1005 is a permanently-installed multi-gas-in-oil analysis system with transformer monitoring functions. It allows for the individual measurement of Moisture in Oil (H2O) and the key gases Hydrogen (H2), Carbon Monoxide (CO), Acetylene (C2H2) and  Ethylene (C2H4) dissolved in transformer oil.

HYDROCAL 1003

The HYDROCAL 1003 is an online monitoring system permanently mounted on the transformer. It measures continuously Moisture in Oil (H2O) and the most important faults gases Hydrogen (H2) and Carbon Monoxide (CO).

HYDROCAL 1001+

The HYDROCAL 1001+ is a permanently-installed composite gas-in-oil sensor for the analysis of six dissolved key fault gases such as Hydrogen (H2), Carbon Monoxide (CO), Methane (CH4), Acethylene (C2H2), Ethylene (C2H4), and Ethane (C2H6). To detect an even wider range of potential transformer faults, the HYDROCAL 1001+ analyses additionally the content of Moisture (H2O) in the transformer oil.

HYDROCAL 1009

The HYDROCAL 1009 is a permanently installed multi-gas-in-oil analysis system with transformer monitoring functions. It individually measures, Moisture in Oil (H2O) and the key gases Hydrogen (H2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Methane (CH4), Acetylene (C2H2), Ethylene (C2H4), Ethane (C2H6) and Oxygen (O2) dissolved in transformer oil.

HYDROCAL 1001+

The HYDROCAL 1001+ is a permanently-installed composite gas-in-oil sensor for the analysis of six dissolved key fault gases such as Hydrogen (H2), Carbon Monoxide (CO), Methane (CH4), Acethylene (C2H2), Ethylene (C2H4), and Ethane (C2H6). To detect an even wider range of potential transformer faults, the HYDROCAL 1001+ analyses additionally the content of Moisture (H2O) in the transformer oil.

HYDROCAL 1009

The HYDROCAL 1009 is a permanently installed multi-gas-in-oil analysis system with transformer monitoring functions. It individually measures, Moisture in Oil (H2O) and the key gases Hydrogen (H2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Methane (CH4), Acetylene (C2H2), Ethylene (C2H4), Ethane (C2H6) and Oxygen (O2) dissolved in transformer oil.

New technologies expand the performance range of Online-DGA-Systems

Article in Transformers Magazine | Vol. 10, Issue 4 | 2023

HYDROCAL 1011 genX P

The HYDROCAL 1011 genX P is a portable device for the analysis of dissolved and free gases from the isolation fluid of oil-filled power transformers and other electrical equipment. It individually measures moisture in oil (H2O) and the key gases hydrogen (H2), carbon monoxide (CO), carbon dioxide (CO2), methane (CH4), acetylene (C2H2), ethylene (C2H4), ethane (C2H6), oxygen (O2), nitrogen (N2) and propane (C3H8) dissolved in transformer oil.

HYDROCAL 1004 genX

The new HYDROCAL 1004 genX is the first truly maintenance-free multi-gas online DGA solution combining proven near infrared (NIR) measuring technology with vacuum protected membrane extraction.
As Hydrogen (H2) is involved in nearly every fault of the insulation system of power transformers and Carbon Monoxide (CO) is a sign of an involvement of the cellulosic / paper isolation the presence and increase of Acetylene (C2H2) further classifies the nature of a fault as overheating, partial discharge or high energy arcing.

HYDROCAL 1006 genX

The new HYDROCAL 1006 genX is the first truly maintenance-free multi-gas online DGA solution combining proven near infrared (NIR) measuring technology with vacuum protected membrane extraction.
As Hydrogen (H2) is involved in nearly every fault of the insulation system of power transformers and Carbon Monoxide (CO) is a sign of an involvement of the cellulosic / paper isolation the presence and increase of Acetylene (C2H2) further classifies the nature of a fault as overheating, partial discharge or high energy arcing.
The additional measurement of Ethylene (C2H4) and Methane (CH4) serves for further analysis, e.g. Duval triangle according IEC 60599.

HYDROCAL 1011 genX P

The HYDROCAL 1011 genX P is a portable device for the analysis of dissolved and free gases from the isolation fluid of oil-filled power transformers and other electrical equipment. It individually measures moisture in oil (H2O) and the key gases hydrogen (H2), carbon monoxide (CO), carbon dioxide (CO2), methane (CH4), acetylene (C2H2), ethylene (C2H4), ethane (C2H6), oxygen (O2), nitrogen (N2) and propane (C3H8) dissolved in transformer oil.

HYDROCAL 1011 genX

The new HYDROCAL 1011 genX is a full-range / maintenance-free multi-gas online DGA solution combining proven near infrared (NIR) measuring technology with miniaturized gas sample production based on headspace principle (no membrane, negative pressure-proofed).
It individually measures Moisture in oil (H2O) and the key gases Hydrogen (H2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Methane (CH4), Acetylene (C2H2), Ethylene (C2H4), Ethane (C2H6), Oxygen (O2), Nitrogen (N2) and Propane (C3H8) dissolved in transformer oil.

HYDROCAL 1008

The HYDROCAL 1008 is a permanently-installed multi-gas-in-oil analysis system with transformer monitoring functions. It allows for the individual measurement of Moisture in Oil (H2O) and the key gases Hydrogen (H2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Methane (CH4), Acetylene (C2H2), Ethylene (C2H4) and  Ethane (C2H6) dissolved in transformer oil.

© 2024 - MTE Meter Test Equipment AG